Product Details:
|
Calibration Wavelength: | 1270 / 1286 / 1290 / 1295 / 1300 / 1305 / 1310 / 1330 / 1510 / 1530 / 1550 / 1570 Nm | Fiber Type: | 9/125 Um Single Mode |
---|---|---|---|
Attenuation Accuracy: | ≤ ± 0.1 DB (0 ~ 25 DB) ≤ ± 0.02 DB (0 ~ 25 DB With Power Control) | Averaging Time Of Monitor PM: | 1~1000ms |
Attenuation Transition Speed: | 0.1 ~ 50 DB/s | Operation Temperature: | 0~ +40 ℃ |
Highlight: | Optically Controlled Optical Attenuator,8 Channel Optically Controlled Optical Attenuator |
4/8 Channel Optically Controlled Optical Attenuator Multiple Devices Can Be Cascaded
Optical Transceiver Testing
In the multi-channel error measurement of optical transceiver module, parallel data measurement is realized;
In the sensitivity measurement of the optical receiving module, a parallel, fast and accurate optical power input is provided;
Optical power control stability time 100 ms, greatly improve test efficiency.
Integrated test of optical network
When integrating and testing network equipment to test network transmission performance and network management.
Features
Fast, accurate settings of attenuation and optical power, Set time: 100 ms
The multi-channel attenuator is set at the same time and multiple ports are simultaneously measured, thus saving a great deal of measurement time.
Built in high-precision OPM ensures the stability and accuracy.
Simple and intuitive graphical user interface, multi-channel data preview, test status is a glance.
Instrument characteristics:
▲The optical attenuation and optical power output can be quickly and accurately set. The optical power control stability time is less than 200 ms.
▲ Multi-channel attenuator is set at the same time, and multiple ports are measured at the same time, saving a lot of measurement time.
▲ Built-in high-precision optical power meter ensures the stability and accuracy of power monitoring.
▲ small size, compact structure, simple operation, intuitive graphical user interface, multi-channel data preview, test status at a glance.
Specification
Model # | U8734 4Ch. | U8738 8Ch. |
Attenuator Range | 0~40 dB | |
Calibration Wavelength |
1270 / 1286 / 1290 / 1295 / 1300 / 1305 / 1310 / 1330 / 1510 / 1530 / 1550 / 1570 nm |
|
Insertion Loss | ≤1.5 dB | |
Fiber Type | 9/125 um single mode | |
Connector Type | FC/UPC Connector | |
Attenuation Accuracy |
≤ ± 0.1 dB (0 ~ 25 dB), ≤ ± 0.02 dB By Power Control |
|
Repeatability | ≤ ±0.02 dB | |
Averaging time of monitor PM | 1~1000ms | |
Settling Time | 100ms | |
Attenuation Transition Speed | 0.1 ~ 50 dB/s | |
Return Loss | > 45 dB | |
Maximum safe input power | +20dBm | |
Communication Interface | RS232, USB,RJ45 Control by PC | |
Recalibration Period | 2 years | |
Operation Temperature | 0~ +40℃ | |
Storage Temperature | -30~+80℃ | |
Power | 100~240 V | |
Dimensions | 235mm W, 55 mm H, 320 mm D | |
Weight | 3.0 kg |
Contact Person: Jack Zhou
Tel: 13602867834
Fax: 86-020-82575318