Product Details:
|
| Wavelength Range(nm): | 1525.00 ~ 1568.00 | Absolute Wavelength Accuracy(pm): | ±10 Pm, Typ. ±5 Pm |
|---|---|---|---|
| Relative Wavelength Accuracy(pm): | ± 5 Pm, Typ. ±2 Pm | Tuning Speed(ms): | ≤ 2 Ms Per Ste |
| Power Repeatability(dB): | ± 0.05 | Relative Noise Intensity(dB): | Typical Value < -135 |
| Output Power(dBm): | 13 | Warranty: | 1 Year |
| Highlight: | 1525nm Laser Scanning Spectrometer,Laser Scanning Spectrometer With 2 Probes |
||
Laser Scanning Spectrometer With 2 Probes Optical Communication Detection
Specification
|
Model # |
UC8512C+UC88201 |
| Adjustable laser light source | |
|
Wavelength range |
1525.00 ~ 1568.00 nm |
|
Output Power |
13 dBm |
|
Wavelength resolution |
1.0 pm |
|
Absolute wavelength accuracy |
±10 pm, Typ. ±5 pm |
|
Relative wavelength accuracy |
± 5 pm, Typ. ±2 pm |
|
Wavelength repeatability |
± 3 pm, typ. ±1 pm |
|
Wavelength stability |
±5 pm (typ., 24 hrs at Constant Temperature) |
| Tuning speed | ≤ 2 ms per step |
|
Power stability |
±0.005dB (15Min) ±0.05 dB ( 24 hours) |
|
Power repeatability |
± 0.05 dB |
|
Power linearity |
± 0.3 dB |
| Power flatness | 0.3 dB; Typical values 0.05dB. |
| Side mode rejection rate | ≥ 40 dBm |
| Relative noise intensity | Typical values < -135 dB |
| Optical power meter | |
| Wavelength range | 850 nm to 1625 nm |
| Power measuring range | +5 dBm to -85 dBm |
| Precision of power | < ± 4% |
| Power repeatability | < 0.1 dB |
| Scanning function: equipped with DWDM/Isolator/GFF device scanning software | |
| Scanning mode |
Fast adjustable laser spectral scanning |
| resolution ratio | 1 pm |
| precision | 5 pm |
| Power display | Peak power display |
| Central wavelength function | Central wavelength and 3dB bandwidth display |
| Reference function | Reference test |
| Power adapter power | AC 100 ~ 240 V , 48 - 66 Hz,100 VA max. |
| display | PC control interface |
| Optical output interface | FC/PC connector |
| Communication interface | USB / RS232 interface |
| Storage temperature | −40°C ~ +80°C |
| Operating temperature | 0°C ~ +45°C |
| Dimensions | 245 mm W, 105 mm H, 320 mm D |
| Weight | 3.0kg |
Rear Panel of the host
![]()
The power supply requirements
The UC8512C+UC88201 complies with overvoltage Level II regulations. The operating voltage is 100 ~ 240V AC voltage, the frequency range is 48 ~ 66Hz, the operating voltage is 115V, the maximum consumption current is 230mA; When the operating voltage is 230V, the maximum consumption current is 120mA.
USB port
The USB interface is a standard 4-core B-type interface, which can be connected to UC8512C+UC88201 and PC, and the instrument can be controlled by monitoring software.
USB connection cable
The length of the USB cable cannot exceed 5 m. Otherwise, only a third-party USB peripheral extender can be used. Generally, the maximum extension length can reach 50 m.
RS232 serial port
The serial port parameters of the instrument are set to a fixed value. The serial port parameter Settings of the computer must match the instrument parameter Settings.
![]()
FAQ
Q: Are you a factory manufacturer?
A: Yes we are manufacturer with 13 years experience in this industry and supplied many good quality products.
Q: Where is your main market?
A: Asia, Europe, America, Middle-East, Africa and other countries and regions.
Q:What is your minimum order quantity (MOQ)?
A: As a standard policy, we accept MOQ of 1set, and mixed items available, it still needs to confirm with our sales according to different product lines.
Q: Can I customize the size and color of the case?
A: Yes. We can discuss it .
Q: Can I buy some samples first before main orders? Is the sample fee refundable?
A: Yes, sample fee and shipment fee should be paid in advance .
Q: How long is the Production Lead Time?
A: 5 days for stock products, different products have different delivery times, according to the actual situation.
Contact Person: Jack Zhou
Tel: +86 4008 456 336