Product Details:
|
| Device Package: | Butterfly | Connector Type: | FC/APC(Other Adaptor Can Be Customized) |
|---|---|---|---|
| Bandwidth@3 DB: | < 0.1 Nm | Bandwidth@20 DB: | < 0.5 Nm |
| SMSR: | > 45 DB(1270nm Etc.) | Optional Wavelength: | 1305/1308 |
| Highlight: | Program Controlled Desktop Optical Attenuator,1.8dB Desktop Optical Attenuator |
||
Program Controlled Optical Attenuator Insertion Loss 1.8dB Accuracy0.1dB
UC8130 Multichannel DFB Laser Source
UC8310/UC8320 desktop optical attenuator is a high precision, wide range optical power attenuation instrument.The new data acquisition and processing method is adopted, which has a larger SNR and a faster response speed, and can reach a large and continuous tunable dynamic attenuation range of 0-60 dB.
The UC8310/UC8320 desktop optical attenuator is mainly used for channel balancing, power balancing, gain slope and power adjustment in DWDM system, as well as optical measurement and application of AWG & PLC components, optical amplifiers and other general optical fibers.
Take UC8310 as an example:
![]()
User Interface Description
Front view of the host
Optical output ports and optical input ports are FC/PC ports.Take UC8310 as an example:
![]()
![]()
The power supply requirements
The UC8310/UC8320 benchtop optical attenuator complies with overvoltage Class II regulations.The operating voltage is 100 ~ 240V AC voltage, the frequency range is 48 ~ 66Hz, the operating voltage is 115V, the maximum consumption current is 230mA;When the operating voltage is 230V, the maximum consumption current is 120mA.
Power Cable Requirements
According to international safety standards, the instrument is equipped with a 3-core power cord that meets national standards.Connect the power cable only to the power socket with ground protection.
Communication interface
USB port
The USB interface is a standard 4-core B-type interface, which can be connected to UC8310/UC8320 and PC, and the instrument can be controlled by monitoring software.
USB connection cable
The length of the USB cable cannot exceed 5 m. Otherwise, only a third-party USB peripheral extender can be used. Generally, the maximum extension length can reach 50 m.
![]()
RS232 serial port
The serial port parameters of the instrument are set to a fixed value.The serial port parameter Settings of the computer must match the instrument parameter Settings.
RS232 interface pin definition
![]()
RS232 is connected to the cable
Definition of connector pin of RS232 connection cable:
| DB9 plug | DB9 pin | ||
| PIN | NOTES | PIN | NOTES |
|
2 |
Received data | 2 | Transmit data |
| 3 | Transmit data | 3 | Received data |
| 5 | Signal ground | 5 | Signal ground |
Note: For serial port communication, use null modem to connect the cable.