Product Details:
|
Product Name: | Light Source Power Meter | Calibration Wavelength: | 850nm 980nm 1310nm |
---|---|---|---|
Power Range: | +10 ~ -65dBm | Linearity (power): | ≤ ± 0.06 DB (1200 Nm ~ 1610 Nm, 0~ -50dBm) |
Fiber Type: | Standard SM And MM Up To 62.5 Um Core Size | Operation Temperature: | 0 ~ +40℃ |
Highlight: | Multiple Channels Optical Power Meter,850nm Optical Power Meter |
8 Channel Multiple channels Optical Power Meter ≤ ± 0.06 dB
Model # | UC8201 | UC8202 | UC8204 | UC820XH |
Number of Channels | 1 | 2 | 4 | X |
Power Range | +10 ~ -65dBm | +25 ~ -50dBm | ||
Wavelength Range | 850 ~ 1700 nm | |||
Calibration Wavelength | 850/980/1310/1490/1550/1610 nm | |||
Application Fiber Type | Standard SM and MM up to 62.5 um core size | |||
Absolute Uncertainty (accuracy) at reference condition |
± 4% (1200 nm ~ 1610 nm) | |||
Relative Uncertainty (accuracy) at reference condition |
< 0.02 dB Typical | |||
Linearity (power) | ≤ ± 0.06 dB (1200 nm ~ 1610 nm, 0~ -50dBm) | |||
Return Loss | > 40 dB | |||
Operation Temperature | 0 ~ +40℃ | |||
Storage Temperature | -30 ~ +80℃ | |||
Recalibration Period | 2 years | |||
Dimensions | 245 mm W, 105 mm H, 320 mm D | |||
Weight | 2.0 kg |
UC8208 channel optical power meters offer superior performance, economical and practical for general purpose of fiber optical test and measurement applications. It is specifically designed for use in high volume production lines.
UC8202/4 optical power meter test systems are efficient, compact sized, fast-starting, and affordable. They provide low power, high power, single channel and dual channel optical power meter options.
The power supply requirements
The UC8208 complies with overvoltage Level II regulations. The operating voltage is 100 ~ 240V AC voltage, the frequency range is 48 ~ 66Hz, the operating voltage is 115V, the maximum consumption current is 230mA; When the operating voltage is 230V, the maximum consumption current is 120mA.
USB port
The USB interface is a standard 4-core B-type interface, which can be connected to UC8208 and PC, and the instrument can be controlled by monitoring software.
USB connection cable
The length of the USB cable cannot exceed 5 m. Otherwise, only a third-party USB peripheral extender can be used. Generally, the maximum extension length can reach 50 m.
RS232 serial port
The serial port parameters of the instrument are set to a fixed value. The serial port parameter Settings of the computer must match the instrument parameter Settings.
RS232 interface pin definition
Contact Person: Jack Zhou
Tel: 13602867834
Fax: 86-020-82575318